Filters and Networks: SCB96367, SC-C-34264, SC-C-62834
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
SCB96367 | 5915-00-701-9135 | Retainer, Electrical Filter | Material: Metal | Kadon Corp. (07912) US Army Communications (80063) | |
SC-C-114847 SCC114847 | 5915-00-897-5669 | Network, Impedance Matching | Special Features: ENCASED;1 variable CAPACITOR;1 inductor Terminal Type and Quantity: 2 turret | Erie Specialty Products Inc. (72982) US Army Communications (80063) | |
SC-C-162328 SCC162328 | 5915-00-779-6433 | Network, Impedance Matching | Special Features: Two connector type terminals, cage 80058 P/N UG-625/U;ALUM case painted GRAY;2.750 in. LF;1.125 in. dia, terminal mtd Impedance Rating in Ohms: 50.0 input and 500.0 output Frequency Range: 10.00 kilohertz minimum and 50000.00 kilohertz maximum | US Army Communications (80063) | |
SC-C-34076 SCC34076 | 5915-00-503-2235 | Filter, Radio Frequency Interfere | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 tab, solder lug input 1ST function 2 tab, solder lug output 2ND function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SC-C-34261 SCC34261 | 5915-00-583-1447 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 turret input 1ST function 2 turret output 2ND function Mounting Facility Type and Quantity: 4 threaded stud | US Army Communications (80063) | |
SCC34263 | 5915-00-186-6465 | Filter, Band Pass | Inclosure Type: Encased Mounting Facility Type and Quantity: 1 threaded stud 1ST function Mounting Facility Screw Thread Series Designator: UNC | US Army Communications (80063) | |
SC-C-34264 SCC34264 | 5915-00-186-6473 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 solder stud input 1ST function 2 solder stud output 2ND function Mounting Facility Type and Quantity: 4 threaded stud | US Army Communications (80063) | |
SCC441881 | 5915-00-070-4539 | Network, Impedance Matching | Special Features: 2 CAPACITORS;3 RESISTORS;3 receptacle coaxial terminals;type UG-625B/U;METAL case | US Army Communications (80063) | |
SCC60560 | 5915-00-197-8610 | Filter, Band Pass | Functional Terminal Type and Quantity: 1 tab, solder lug input 1ST function 1 tab, solder lug output 2ND function 1 tab, solder lug ground 3RD function Reference Frequency per Function: 1.125 kilohertz blank Frequency Band Width per Function: 250.00 hertz blank and 2.500 kilohertz blank | US Army Communications (80063) | |
SC-C-62526 SCC62526 | 5915-00-501-4345 | Filter, low Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 1 tab, solder lug input 1ST function 1 tab, solder lug output 2ND function 2 tab, solder lug ground 3RD function Mounting Facility Type and Quantity: 2 threaded bushing | American Telephone and Telegraph Co. (64959) At and T Corp. (70408) US Army Communications (80063) | |
SC-C-62527 SCC62527 | 5915-00-501-4338 | Filter, low Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 1 tab, solder lug input 1ST function 1 tab, solder lug output 2ND function 2 tab, solder lug ground 3RD function Mounting Facility Type and Quantity: 2 threaded hole | US Army Communications (80063) | |
SC-C-62529 SCC62529 | 5915-00-356-2156 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 1 tab, solder lug input 1ST function 1 solder stud output 2ND function 2 solder stud ground 3RD function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SC-C-62530 SCC62530 | 5915-00-281-0279 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 1 tab, solder lug input 1ST function 1 tab, solder lug output 2ND function 2 tab, solder lug ground 3RD function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SC-C-62531 SCC62531 | 5915-00-281-0278 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 tab, solder lug input 1ST function 2 tab, solder lug output 2ND function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SCC62543 | 5915-00-281-0251 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 1 solder stud input 1ST function 1 solder stud output 2ND function 2 solder stud ground 3RD function Mounting Facility Type and Quantity: 1 threaded stud 1ST function | US Army Communications (80063) | |
SCC62801 | 5915-00-356-2157 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 tab, solder lug input 1ST function 2 tab, solder lug output 2ND function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SC-C-62802 SCC62802 | 5915-00-356-2171 | Filter Assembly, Electrical | Special Features: Capable of selecting 1 khz, 7 khz, 11 khz, 19 khz, only one of these five freq shall be selected at any one time, external connection for these freq shall be accomplished by a switch not supplied W/the filter, insertion loss 0.6 db max, 600 ohms impedance, -65 deg F to plus 185 deg F operating temp RANGE;ENCASED;6 solder lug TERMINALS;2 no. 10/0.190 IN./-32 thd mtg STUDS;3.406 IN.LG;1.438 in. W;3.156 in.H incl mtg studs;inductance-capacitance type circuitry | US Army Communications (80063) | |
SCC62803 | 5915-00-356-2161 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 tab, solder lug input 1ST function 2 tab, solder lug output 2ND function 1 tab, solder lug ground 3RD function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SC-C-62832 SCC62832 | 5915-00-295-7006 | Filter, low Pass | Inclosure Type: Encased Functional Terminal Type and Quantity: 1 tab, solder lug input 1ST function 1 tab, solder lug output 2ND function 2 tab, solder lug ground 3RD function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) | |
SC-C-62834 SCC62834 | 5915-00-356-2158 | Filter, Band Pass | Inclosure Type: Hermetically sealed Functional Terminal Type and Quantity: 2 tab, solder lug input 1ST function 2 tab, solder lug output 2ND function Mounting Facility Type and Quantity: 2 threaded stud | US Army Communications (80063) |