Circuit Breakers: FAL365016M, FAZ-2-C16-FIMO.03, FAZ - B6
| MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ | 
|---|---|---|---|---|---|
| FAL365016M | 5925-01-287-6631 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 50.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 600.0 ac all locations  | Schneider Electric USA Inc. (56365) | |
| FA-M01                           FAM01  | 5925-01-038-0677 | Tripper, Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 30.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 120.0 ac all locations  | Schneider Electric USA Inc. (56365) Square D Co. (51918)  | |
| FAP36015 | 5925-00-222-6199 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 15.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 600.0 ac all locations  | Schneider Electric USA Inc. (63637) Square D Co. (51918)  | |
| FAP36050 | 5925-00-209-0435 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 50.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 600.0 ac all locations  | Schneider Electric USA Inc. (63637) Square D Co. (51918)  | |
| FAZ -1N - C2                     FAZ1NC2  | 5925-01-457-7373 | Circuit Breaker | Klockner-Moeller Corp. (57715) | ||
| FAZ - 2 - B10                    FAZ2B10  | 5925-01-449-1152 | Circuit Breaker | Maximum Continuous Load Current Rating per Pole: 10.0 amperes ac all locations | Klockner-Moeller Corp. (57715) | |
| FAZ - 2- B6                      FAZ2B6  | 5925-01-450-4759 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 6.0 amperes ac all locations  | Klockner-Moeller Corp. (57715) | |
| FAZ-2-C10                        FAZ2C10  | 5925-01-533-0650 | Circuit Breaker | III End Item Identification: Agavgcrew shelter (inls) KDF208680-M | Klockner-Moeller Corp. (57715) | |
| FAZ-2-C16-FIMO.03                FAZ2C16FIMO03  | 5925-01-535-6212 | Circuit Breaker | Operating Voltage Type and Rating per Pole in Volts: 400.0 ac all locations Frequency in Hertz: 60.0 all locations III End Item Identification: Auxiliary control assembly  | Moeller Electric Corp. (57836) | |
| FAZ-2-C6                         FAZ2C6  | 5925-01-533-0656 | Circuit Breaker | III End Item Identification: Agavgcrew shelter (inls) KDF208680-M | Klockner-Moeller Corp. (57715) | |
| FAZ - 3 - C1                     FAZ3C1  | 5925-01-457-5165 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 1.0 amperes ac all locations  | Klockner-Moeller Corp. (57715) | |
| FAZ - 3 - C16                    FAZ3C16  | 5925-01-481-6732 | Circuit Breaker | III End Item Identification: Contractor logistic support model M871, 30-FOOT trailer laundry advanced system (ladds), nsn 2330-00-122-6779 contract DAAK60-97-C-9222 tm 9-9510-122-24P | Klockner-Moeller Corp. (57715) | |
| FAZ - 3 - C20                    FAZ3C20  | 5925-01-481-6734 | Circuit Breaker | III End Item Identification: Contractor logistic support model M871, 30-FOOT trailer laundry advanced system (ladds), nsn 2330-00-122-6779 contract DAAK60-97-C-9222 tm 9-9510-122-24P | Klockner-Moeller Corp. (57715) | |
| FAZ-3-C20                        FAZ3C20  | 5925-01-456-5851 | Circuit Breaker | III End Item Identification: 3510-01-365-5687, fscm 90598 | Moeller Electric Corp. (57836) | |
| FAZ - 3 - C4                     FAZ3C4  | 5925-01-457-7363 | Circuit Breaker | Klockner-Moeller Corp. (57715) | ||
| FAZ - 3 - C40                    FAZ3C40  | 5925-01-481-6736 | Circuit Breaker | III End Item Identification: Contractor logistic support model M871, 30-FOOT trailer laundry advanced system (ladds), nsn 2330-00-122-6779 contract DAAK60-97-C-9222 tm 9-9510-122-24P | Klockner-Moeller Corp. (57715) | |
| FAZ-3-C50                        FAZ3C50  | 5925-01-535-8420 | Circuit Breaker | Pole Quantity: 3 Trip Release Method: Thermal-magnetic all locations Circuit Protection Type: Overcurrent all locations  | Lockheed Martin Corporation (03538) Moeller Electric Corp. (57836)  | |
| FAZ - 3 - C6                     FAZ3C6  | 5925-01-457-5168 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 6.0 amperes ac all locations  | Klockner-Moeller Corp. (57715) | |
| FAZ - 3 - C63                    FAZ3C63  | 5925-01-481-6735 | Circuit Breaker | III End Item Identification: Contractor logistic support model M871, 30-FOOT trailer laundry advanced system (ladds), nsn 2330-00-122-6779 contract DAAK60-97-C-9222 tm 9-9510-122-24P | Klockner-Moeller Corp. (57715) | |
| FAZ - B6                         FAZB6  | 5925-01-449-1149 | Circuit Breaker | Maximum Continuous Load Current Rating per Pole: 6.0 amperes ac all locations | Klockner-Moeller Corp. (57715) |