Circuit Breakers: EHD3080H09, EHD3090, EMC8-3-0.050
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
EHD3080H09 | 5925-01-562-3527 | Circuit Breaker | Eaton Corporation (1TMY5) | ||
EHD3080LVH08 | 5925-01-439-2135 | Circuit Breaker | Pole Quantity: 3 | DRS Power & Control Technologies (27192) | |
EHD3080VH08 | 5925-01-460-5465 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 80.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 480.0 ac all locations | Eaton Corporation (89946) | |
EHD3080VH09 | 5925-01-502-3074 | Circuit Breaker | Special Features: 100 amp frame; 3 pole; 480 vac; 80 amp trip calibrated for 50 degrees C.; naval labeled; vibration tested; calibrated for 50 degrees C.; terminal magnet breaker; frequency 60 hz; molded case | Eaton Corporation (89946) | |
EHD3090 | 5925-01-480-4016 | Circuit Breaker | III End Item Identification: Starter mtr | Eaton Corp. (68592) | |
EHD3090V | 5925-00-135-6184 | Circuit Breaker | Body Style: 11B multipole-single actuator type Body Width: 4.125 inches nominal Body Length: 6.000 inches nominal | Eaton Corporation (89946) | |
EHD3100 | 5925-01-133-6425 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 100.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 480.0 ac all locations | DRS Power & Control Technologies (27192) Eaton Corporation (89946) Swam Electric Co. Inc. (04018) | |
EHD3100H08 | 5925-01-439-2136 | Circuit Breaker | Pole Quantity: 3 | DRS Power & Control Technologies (27192) | |
EHD3100H09 | 5925-01-562-3525 | Circuit Breaker | Eaton Corporation (1TMY5) | ||
EHD3100KL WITH A2X1RB EHD3100KLWITHA2X1RB | 5925-01-374-7001 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 100.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 480.0 ac all locations | Eaton Corporation (89946) | |
EHD3100L | 5925-00-211-1900 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 100.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 480.0 ac all locations | Eaton Corporation (89946) | |
EHD3100VH08 | 5925-01-460-5046 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 100.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 480.0 ac all locations | Eaton Corporation (89946) | |
EHD3100VH09 | 5925-01-502-3077 | Circuit Breaker | Special Features: 100 amp frame; 3 pole; 480 vac; 100 amp trip calibrated for 50 degrees C.; naval labeled; vibration testd; calbrated for 50 degrees C.; terminal magnetic breaker; frequency 60 hz; molded case | Eaton Corporation (89946) | |
EHH0166 | 5925-00-230-7629 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 7.5 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations | DLA Land and Maritime (16236) | |
EHH0166 | 5925-00-484-7644 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 7.5 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations | DLA Land and Maritime (16236) | |
EHH0166 | 5925-00-484-7645 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 7.5 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations | DLA Land and Maritime (16236) | |
EHH0166 | 5925-00-572-6118 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 70.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations | DLA Land and Maritime (16236) | |
EHR 1005 EHR1005 | 5925-01-539-6972 | Circuit Breaker | End Item Identification: Unknown Part Name Assigned BY Controlling Agency: Circuit breaker | Federal Prison Industries Inc. (90142) | |
EHS-B060 EHSB060 | 5925-01-416-2814 | Circuit Breaker | SPD Electrical Systems Inc. (30086) | ||
EKK8300 | 5925-00-324-2246 | Circuit Breaker | Circuit Protection Type: Overcurrent all locations | Siemens-Energy and Automation Inc. (91623) | |
EL1302 ITEM 7 EL1302ITEM7 | 5925-01-445-0063 | Circuit Breaker | Maximum Continuous Load Current Rating per Pole: 40.0 amperes ac single location | Westmont Industries (34003) | |
ELN-ETA6A ELNETA6A | 5925-01-477-1673 | Circuit Breaker | George Knight & Co. (34028) | ||
EMC8-3-0.050 EMC830050 | 5925-00-726-0100 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 50.0 milliamperes ac and 50.0 milliamperes dc single location Operating Voltage Type and Rating per Pole in Volts: 120.0 ac and 32.0 dc single location | Sensata Technologies Inc. (82647) |