Circuit Breakers: AP12-1RC-62-203, AP1-222-4, AP12-22502-1
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
AP12-1RC-62-203 AP121RC62203 | 5925-01-536-3198 | Circuit Breaker | III End Item Identification: Chassis, proc pwr dist III Part Name Assigned By Controlling Agency: 20 amp, 120V, 2 pole cb | Airpax Corp. (0LCZ9) | |
AP12-1RC-62-502 AP121RC62502 | 5925-01-530-5151 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 5.0 amperes ac single location Operating Voltage Type and Rating per Pole in Volts: 120.0 ac single location | Airpax Corp. (0LCZ9) | |
AP-12-1RC-64F-203 AP121RC64F203 | 5925-01-450-6462 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 20.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 240.0 ac and 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP12-1RC-65-103 AP121RC65103 | 5925-01-484-0210 | Circuit Breaker | Pole Quantity: 2 III End Item Identification: Sawari 2 Special Features: Fully sealed; 2 pole unit; cane hook terminals; 50/60 hz high pulse; nominal amp rating 10, 000 | Sensata Technologies Maryland Inc. (81541) | |
AP-12-1RC-65F-203 AP121RC65F203 | 5925-01-216-2172 | Circuit Breaker | Sensata Technologies Maryland Inc. (81541) | ||
AP1-2200-3 AP122003 | 5925-01-038-1352 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating PER Pole: 5.0 amperes ac single location and 5.0 amperes dc single location Operating Voltage Type AND Rating PER Pole IN Volts: 240.0 ac single location and 50.0 dc single location | Sensata Technologies Maryland Inc. (81541) | |
AP-12-20475-1 AP12204751 | 5925-01-183-6331 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 7.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 240.0 ac all locations | Sensata Technologies Maryland Inc. (81541) | |
AP12-20584-1 AP12205841 | 5925-01-345-4975 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 2.0 amperes ac first location 4.0 amperes dc second location Operating Voltage Type and Rating per Pole in Volts: 240.0 ac first location 50.0 dc second location | Sensata Technologies Maryland Inc. (81541) | |
AP12-206-1 AP122061 | 5925-00-192-0767 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 10.0 amperes dc all locations Operating Voltage Type and Rating per Pole in Volts: 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP122061ETC | 5925-00-192-0767 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 10.0 amperes dc all locations Operating Voltage Type and Rating per Pole in Volts: 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP-12-21074-1 AP12210741 | 5925-01-254-6590 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 5.0 amperes dc first location 1.0 amperes ac second location Operating Voltage Type and Rating per Pole in Volts: 50.0 dc first location 250.0 ac second location | Sensata Technologies Maryland Inc. (81541) | |
AP12-21274-1 AP12212741 | 5925-01-246-3522 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 3.0 amperes ac and 3.0 amperes dc first location 8.0 amperes ac and 8.0 amperes dc second location Operating Voltage Type and Rating per Pole in Volts: 240.0 ac and 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP12-216 AP12216 | 5925-01-049-7364 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 6.0 amperes ac and 6.0 amperes dc all locations Operating Voltage Type and Rating per Pole in Volts: 240.0 ac and 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP12-216-3 AP122163 | 5925-01-049-7364 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 6.0 amperes ac and 6.0 amperes dc all locations Operating Voltage Type and Rating per Pole in Volts: 240.0 ac and 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP12-21904-5 AP12219045 | 5925-01-262-0759 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 14.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 240.0 ac all locations | Sensata Technologies Maryland Inc. (81541) | |
AP12-2200-2 AP1222002 | 5925-01-081-3690 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 7.5 amperes dc first location 2.5 amperes dc second location Operating Voltage Type and Rating per Pole in Volts: 50.0 dc all locations | Sensata Technologies Maryland Inc. (81541) | |
AP1-222-22 AP122222 | 5925-01-024-4153 | Circuit Breaker | Thread Pitch Diameters: +0.3503 to 0.3537 inches Body Style: Single pole type Bushing Length: 0.332 inches minimum and 0.380 inches maximum | Sensata Technologies Maryland Inc. (81541) | |
AP12-22380-1 AP12223801 | 5925-01-339-3081 | Circuit Breaker | Pole Quantity: 2 Trip Release Method: Magnetic all locations Circuit Protection Type: Overcurrent all locations | Sensata Technologies Maryland Inc. (81541) | |
AP1-222-4 AP12224 | 5925-00-911-8807 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 1.0 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 50.0 dc single location | Sensata Technologies Maryland Inc. (81541) | |
AP12-22502-1 AP12225021 | 5925-01-339-3080 | Circuit Breaker | Pole Quantity: 2 Trip Release Method: Magnetic all locations Circuit Protection Type: Overcurrent all locations | Sensata Technologies Maryland Inc. (81541) |