Circuit Breakers: 806599-1, 807-0069, 8090536
| MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ | 
|---|---|---|---|---|---|
| 806599-1                         8065991  | 5925-01-166-2217 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 15.0 amperes ac and 15.0 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 250.0 ac and 28.0 dc single location  | Raytheon Company (96214) | |
| 806599-3                         8065993  | 5925-01-166-2219 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 5.0 amperes ac and 28.0 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 250.0 ac and 28.0 dc single location  | Raytheon Company (96214) | |
| 806599-4                         8065994  | 5925-01-166-2218 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 15.0 amperes ac and 15.0 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 250.0 ac and 28.0 dc single location  | Raytheon Company (96214) | |
| 806599-5                         8065995  | 5925-01-165-1765 | Circuit Breaker | Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 10.0 amperes ac and 10.0 amperes dc all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac first location 250.0 ac and 28.0 dc second location 250.0 ac third location  | Raytheon Company (96214) | |
| 806863 | 5925-01-536-1604 | Marf Battery | Criticality Code Justification: ZZZY Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications  | SPD Electrical Systems Inc. (30086) | |
| 807-0069                         8070069  | 5925-01-432-2731 | Circuit Breaker | Frymaster/Dean (95284) | ||
| 807141 | 5925-01-047-7510 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 1.0 amperes ac and 1.0 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 250.0 ac and 50.0 dc single location  | L-3 Communications Cincinnati (80045) | |
| 807141-2                         8071412  | 5925-00-866-2198 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 1.5 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 50.0 dc single location  | L-3 Communications Cincinnati (80045) | |
| 8071814-001                      8071814001  | 5925-01-144-9135 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 20.0 amperes ac single location Operating Voltage Type and Rating per Pole in Volts: 120.0 ac single location  | Ogden Air Logistics Center (98747) Thales Training & Simulation LTD (K1182)  | |
| 80-7365                          807365  | 5925-01-197-8404 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 15.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 120.0 ac and 240.0 ac all locations  | Department of Defense Project (30554) | |
| 807387 | 5925-00-865-1333 | Circuit Breaker | Westinghouse Electric Corp. (79500) | ||
| 80-7458                          807458  | 5925-01-218-6427 | Circuit Breaker | Special Features: Circuit breaker, vacuum draw out type, rated at 1200 amperes continuous, voltage rating 4.16KV and 250 mva interrupting, trip coil 24 vdc nominal, 30 amps max, closing coil 120 vac 50/60 hz 6 amps max manual operation: crank handle furnished for closing, tripping, charging and drawing-out circuit breaker | Department of Defense Project (30554) | |
| 80-7458-01                       80745801  | 5925-01-218-6427 | Circuit Breaker | Special Features: Circuit breaker, vacuum draw out type, rated at 1200 amperes continuous, voltage rating 4.16KV and 250 mva interrupting, trip coil 24 vdc nominal, 30 amps max, closing coil 120 vac 50/60 hz 6 amps max manual operation: crank handle furnished for closing, tripping, charging and drawing-out circuit breaker | Department of Defense Project (30554) | |
| 80-7637-01                       80763701  | 5925-01-198-7912 | Circuit Breaker | Pole Quantity: 1 Circuit Protection Type: Overcurrent single location Case Material: Plastic  | Department of Defense Project (30554) | |
| 80-7637-02                       80763702  | 5925-01-198-6970 | Circuit Breaker | Pole Quantity: 1 Circuit Protection Type: Overcurrent single location Case Material: Plastic  | Department of Defense Project (30554) | |
| 8077 | 5925-01-525-7694 | Circuit Breaker | III End Item Identification: Boat, patrol, 25 foot | Blue Sea Systems Inc. (1Q449) | |
| 8078724ITEM6 | 5925-00-300-5176 | Tripper, Circuit Breaker | General Electric Co. (24446) | ||
| 8079 | 5925-00-174-8803 | Circuit Breaker | Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 5.0 amperes dc single location Operating Voltage Type and Rating per Pole in Volts: 30.0 dc single location  | Cessna Aircraft Co. (00781) | |
| 80-7983                          807983  | 5925-01-234-8312 | Circuit Breaker | Pole Quantity: 2 Maximum Continuous Load Current Rating per Pole: 100.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 240.0 ac all locations  | Department of Defense Project (30554) | |
| 8090536 | 5925-01-096-4675 | Circuit Breaker | Body Style: Single pole type Body Length: 6.310 inches nominal Body Width: 1.370 inches minimum and 1.380 inches maximum  | U S Army Aviation and Missile (18876) |