Circuit Breakers: 10-270-4, 10-30108-5, 1031

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
10-270-4
102704
5925-00-418-1531Thermal Release, Circuit BreakerOverall Length: 1.750 inches nominal
Overall Width: 0.375 inches nominal
Overall Depth: 0.875 inches nominal
Eaton Corp. (15605)

Quote

10273084-1
102730841
5925-01-232-3590Actuator, Electro-Mechanical, lineEnd Item Identification: Patriot, surface to air missile
U S Army Aviation and Missile (18876)

Quote

10273084-3
102730843
5925-01-232-2204Actuator, Electro-Mechanical, lineSimmonds Precision Products Inc. (12511)
U S Army Aviation and Missile (18876)

Quote

10279758 5925-00-476-8081Circuit BreakerPole Quantity: 6
Maximum Continuous Load Current Rating per Pole: 20.0 amperes ac all locations
Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations
U S Army Aviation and Missile (18876)

Quote

10282558-19
1028255819
5925-01-046-0089Circuit BreakerPole Quantity: 2
Maximum Continuous Load Current Rating per Pole: 5.0 amperes dc all locations
Operating Voltage Type and Rating per Pole in Volts: 270.0 dc all locations
U S Army Aviation and Missile (18876)

Quote

10282558-20
1028255820
5925-01-046-6905Circuit BreakerPole Quantity: 3
Maximum Continuous Load Current Rating per Pole: 60.0 amperes ac all locations
Operating Voltage Type and Rating per Pole in Volts: 240.0 ac all locations
U S Army Aviation and Missile (18876)

Quote

10282558-9
102825589
5925-01-044-9167Circuit BreakerPole Quantity: 2
Maximum Continuous Load Current Rating per Pole: 10.0 amperes dc all locations
Operating Voltage Type and Rating per Pole in Volts: 270.0 dc all locations
U S Army Aviation and Missile (18876)

Quote

102886 5925-00-107-4234Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 3.0 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 50.0 dc single location
ITT Telecom Products Corp. (21340)

Quote

1029 5925-01-325-7607Thermal, OverloadEaton Corp. (15605)

Quote

10-30099
1030099
5925-00-810-4729Circuit BreakerPole Quantity: 3
Maximum Continuous Load Current Rating per Pole: 350.0 amperes ac all locations
Operating Voltage Type and Rating per Pole in Volts: 200.0 ac all locations
The Boeing Company (81205)

Quote

10-30108-15
103010815
5925-00-943-0250Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 15.0 amperes ac and 15.0 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 200.0 ac and 28.0 dc single location
The Boeing Company (81205)

Quote

10-30108-2
10301082
5925-00-766-8538Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 2.5 amperes ac and 2.5 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 200.0 ac and 28.0 dc single location
The Boeing Company (82918)

Quote

10-30108-20
103010820
5925-01-095-6397Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 20.0 amperes ac and 20.0 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 120.0 ac and 30.0 dc single location
The Boeing Company (81205,82918)

Quote

10-30108-35
103010835
5925-00-985-8269Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 35.0 amperes ac and 35.0 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 115.0 ac and 28.0 dc single location
The Boeing Company (82918)

Quote

10-30108-5
10301085
5925-01-107-6623Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 5.0 amperes ac and 5.0 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 200.0 ac and 28.0 dc single location
The Boeing Company (82918)

Quote

10-30108-7
10301087
5925-01-569-2981Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 7.5 amperes ac single location
Trip Release Method: Thermal-magnetic single location
The Boeing Company (82918)

Quote

103030-1
1030301
5925-01-068-0943Circuit BreakerPole Quantity: 2
Maximum Continuous Load Current Rating per Pole: 10.0 amperes ac all locations
Operating Voltage Type and Rating per Pole in Volts: 240.0 ac all locations
Herley Industries Inc. (24469)
Vega Precision Laboratories Inc. (23115)

Quote

10-30453-5
10304535
5925-00-462-0691Circuit BreakerPole Quantity: 3
Maximum Continuous Load Current Rating per Pole: 5.0 amperes ac all locations
Operating Voltage Type and Rating per Pole in Volts: 205.0 ac all locations
The Boeing Company (81205,82918)

Quote

10-30460-75
103046075
5925-00-448-2252Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 75.0 amperes dc single location
Operating Voltage Type and Rating per Pole in Volts: 30.0 dc single location
The Boeing Company (82918)

Quote

1031 5925-00-257-6586Circuit BreakerPole Quantity: 1
Maximum Continuous Load Current Rating per Pole: 30.0 amperes ac single location
Operating Voltage Type and Rating per Pole in Volts: 240.0 ac single location
Challenger Electrical Equipment Corp. (21810)

Quote